SENKRON, Gemi Pano, Elektrik, Taahhüt, Proje ve Mühendislik
Home e-mail Türkçe English
 
SENKRON, Gemi Pano, Elektrik, Taahhüt, Proje ve Mühendislik
Services
    Panel Manufacturing
    Project Engineering
    Electric Project Undertake
    Maintenance and Repairing
Products
    Ships Applications
    Alarm monitoring system
    Bow thruster controller
    Electronic bridge telegraph
    Electronic signal column
    Main & emergency switch board
    Wheelhouse, radio, ECR desks
    Industrial Applications
    Frequency converters
    EVE frequency converters
    12 Plus Frequency converters
    Controllers
    Mitsubishi Products
    Low voltage switch gears
    ELEQ Products
    Measuring Instruments
    Measuring Transducers
    Current Transformers
    AIK Products
    Guaquello 950 fire stop system
    NORIS Products
    Alarm monitoring and
      propulsion systems
    STUCKE ELEKTRONIK Products
    Symap generator automation
      systems
    TQ Products
    Gas monitoring system
    ALPHATECHNIQUE Products
    Tank monitoring and cargo
      handling system
    GMW GOSSEN Products
    Measuring Instruments
    Measuring Transducers
    Current Transformers
    HANSHIN Products
    Marine internal communication
      systems
    HAIXING Products
    Marine lighting fixtures

Geaquello SistemiKablo yolları ve geçitleri için yangın duvarı

GEAQUELLO SYSTEM

Installation and Design Summary of the Geaquello® System Schematic Representation for Cables

Cable penetrations:

  • fireproof
  • gastight
  • watertight
  • nontoxic

Top: Set up the penetrating cables by insertion of the swell modules at both ends of the penetration



Center: Spray-soak swell modules with impregnation liquid E824 to form a damming barriers. The swollen swell modules automatically provide the proper spacing between the cables and between the cables and the metal penetration ducts and act as damming material at both ends of the penetration.



Bottom: From hole on the top, pour 2-part E950/1-part water cement-like mixture in between the damming barriers filling the voids between the damming modules with the sealing compound E950. A solid fire seal will form upon drying.

Installation Detail For Geaquello System for Cables



Sealing the Penetration

Flammadur E292 is a two component polyurethane resin which is used to seal through mechanical parts in penetrations to protect them from fire within the penetration.

Properties:
Flammadur E292 is flexible flame retardant which has excellent resistance to water, contains no asbestos or harmful solvents. Avoid contact with bare skin and eyes, for details, please consult Material Safety Data Sheet.

Non Toxic:
Contains no asbestos or harmful solvents. Avoid contact with bare skin and eyes.

Instructions:
The hardener is contained in a small chamber that is effectively the lid of the main container. Remove the plastic cap in the lid with a screwdriver or similar tool, and puncture the base of the lid. Its contents, the hardener, will drain into the resin in the container. Remove the metal clamp and the lid from the container. Stir the compound until the mixture reaches an even color indicating that the mixture is homogeneous. Do not leave any of the resin in the bottom of the container. After the resin and the hardner have been weel mixed, use immediately. Tools and spills must be cleaned with an organic solvent. Apply the mixture by pouring directly from the can or with the aid of a hand pump. No special equipment is needed. Do not apply below 5ºC (41ºF).

Spraying:
Special spraying equipment can be used to spray a mixture of 7.25 parts resin to one part of hardener. Application on ships in Geaquello System for passage through bulkheads and decks: For cables E292 is used on a deck, on the top of E950 for a depth of 10 mm (see Fig. 3b in Geaquello System, under heading of Transit Box) For electric busway in Geaquello System, under heading Electric Busway, for a depth of 110 mm

Material Composition High fill polyurethane
Final Color Brown
Consistency Liquid resin
Required Additive Ready made
Mixing Ratio by weight
Mixing Ratio by volume
9 parts resin to 1 part hardener
7.75 parts resin to 1 part hardener
Pot Life at 68ºF (20ºC) 40- 60 minutes
Cure Time at 68ºF (20ºC) 16-24 hours
Shelf Life 1 year in closed container
Final Density Hardner, A
Resin, B
Cured
1.22 g/cm³
1.70 g/cm³
1.65 g/cm³
Shearing Strength
Concrete
Steel Pipe
Psi:350   kPa: 2,400
Psi:2,150   kPa: 14,840
Resistance to Water Penetration 689 kPa for 24 hours
(100 psi for 24 hours)
Gamma Ray Extinction
Coefficient (decadic)
Co60
Cs137


12.0 inch.( 31 cm)
9.1 inch. (23 cm)
Cleaning Solvent Organic Solvent
Retrofit Yes
Life Expectancy 50 years
Application Method Manual or by pump
Gamma Ray Resistance - Exposure to 200 million rads (equivalent to the average cumulative dose for an exposure of 40 years in nuclear power plant) shows no change in mechanical and chemical properties.
Certificates
Nr. 02-HG308515-PDA_ABS
Nr. 01865_E1_Bureau Veritas
Nr. 33 245 84 HH_Germanischer Lloyd
Nr. 42 912 - 02_GL Luxembourg
Nr. HMB02696-FP001_Korean Register Of Shipping
Nr. SAS F020409_Lloyd´s Register
Nr. T.C.292.J1.040_Canada
Nr. F-16727_DNV
Nr. 01EQ277FPA_NKK
Nr. 02.036.250_RMRS
Nr. 164.138/EC 0801/42912-02Lux_USCG